Search results for "Icd implantation"

showing 2 items of 2 documents

ICD Implantation in infants and small children: the extracardiac technique.

2007

There is no clear methodology for implantation of an internal cardioverter-defibrillator (ICD) in infants and small children. The aim of this study was to assess efficacy and safety of an extracardiac ICD implantation technique in pediatric patients.An extracardiac ICD system was implanted in eight patients (age: 0.3-8 years; body weight: 4-29 kg). Under fluoroscopic guidance a defibrillator lead was tunneled subcutaneously starting from the anterior axillar line along the course of the 6th rib until almost reaching the vertebral column. After a partial inferior sternotomy, bipolar steroid-eluting sensing and pacing leads were sutured to the atrial wall (n = 2) and to the anterior wall of t…

Malemedicine.medical_specialtyDefibrillationmedicine.medical_treatmentAnterior wallElectric Countershock030204 cardiovascular system & hematologyProsthesis Implantation03 medical and health sciences0302 clinical medicinemedicineHumans030212 general & internal medicineLead (electronics)Childbusiness.industrySmall childrenInfantArrhythmias CardiacGeneral MedicineImplantable cardioverter-defibrillator3. Good healthIcd implantationSurgeryDefibrillators Implantablemedicine.anatomical_structureTreatment OutcomeVentricleChild PreschoolFemaleCardiology and Cardiovascular MedicinebusinessVertebral columnPacing and clinical electrophysiology : PACE
researchProduct

ICD Implantation in Noncompaction of the Left Ventricular Myocardium: A Case Report

2009

Isolated noncompaction of the ventricular myocardium (INVM) is an uncommon cardiomyopathy characterized by the persistence of fetal myocardium with prominent trabecular meshwork and deep intertrabecular recesses, often associated with systolic dysfunction and ventricular dilatation. A 23-year-old man from Burkina Faso was referred to our operative unit with a diagnosis of INVM, made with echocardiogram and magnetic resonance imaging and nonsustained ventricular tachycardia. The literature reports the incidence of malignant ventricular arrhythmias in as many as 47% of the patients and sudden cardiac death in almost 50% of them and this supported our decision to perform implantable cardiovert…

medicine.medical_specialtymedicine.diagnostic_testbusiness.industryVentricular dilatationCardiomyopathyMagnetic resonance imagingGeneral Medicinemedicine.diseaseVentricular tachycardiaSudden cardiac deathIcd implantationmedicine.anatomical_structureInternal medicinecardiovascular systemmedicineLeft ventricular myocardiumCardiologycardiovascular diseasesTrabecular meshworkCardiology and Cardiovascular MedicinebusinessPacing and Clinical Electrophysiology
researchProduct